Filter Results By:

Products

Applications

Manufacturers

Contact Resistance

opposition to the flow of heat or electricity within a connection.


Showing results: 136 - 150 of 236 items found.

  • PXI Dual 32x4 Matrix 1-Pole Screened

    40-534A-021-S - Pickering Interfaces Ltd.

    Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.

  • PXI Dual 32x4 Matrix 2-Pole Switching

    40-534A-022 - Pickering Interfaces Ltd.

    Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.

  • Wristat Tester

    WT25 - Walter G. Legge Company Inc.

    The WT25 WRISTAT Tester is designed to test the integrity of our WRISTAT in a fast, efficient and simple manner. All of the elements of the WRISTAT - continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact are easily confirmed by pressing the top cover of the WT25. The operator (wearer) is tested for a resistance to ground of greater than 750K ohms and less than 10M (switchable to 100M ohms).

  • Wafer Test Solutions

    IQtouch - Johnstech International Corporation

    The new IQtouch™ Micro Final Test Probe Arrays, for example, deliver unsurpassed low and stable contact resistance (CRES). This is accomplished through a balanced optimization among several critical and competing engineered parameters, including effective test signal transmission path, probe / wafer interface (“touch”) points and elastomeric web forces, and precision manufactured components for superior X/Y/Z co-planarity

  • PXI Single 55x8 Matrix 1-Pole Switching

    40-538-021 - Pickering Interfaces Ltd.

    The 40-538 ultra high density matrix module is configured as a Single 55x8 reed relay matrix with 1-pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e8 operations to give maximum switching confidence with long life and stable contact resistance.

  • Chroma Milliohm Meters

    Chroma Systems Solutions, Inc.

    The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.

  • Connectors

    Panasonic Automotive & Industrial Systems Europe GmbH

    : They have to be as compact as possible and provide maximum reliability. To fulfil these requirements, Panasonic engineers have developed narrow-pitch connectors that utilize TOUGH CONTACT technology.In addition to their excellent shock and vibration resistance, these connectors feature an ultra slim profile, which makes them ideally suited for applications where space is valuable. Our versatile in-device connector product range offers the appropriate solution for practically any scenario.

  • PXI Ultra High Density 64x2 2-Pole Matrix

    40-533B-032 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Ultra High Density 64x2 1-Pole Matrix

    40-533B-031 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI 6U PXI High Density Matrix, 132x8 1-Pole

    45-541-001 - Pickering Interfaces Ltd.

    This 6U PXI Reed Relay Matrix Module is an ultra high-density reed relay matrix available in 132x8 format with 1- pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e9 operations to give maximum switching confidence with long life and stable contact resistance.

  • Ultra High Density 64x4 1-Pole PXI Matrix

    40-533B-021 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • Martindale Abrasion Pilling Tester

    TESTEX Testing Equipment Systems Ltd.

    Martindale Abrasion Tester, to determine the abrasion and pilling resistance of all kinds of textile structures. Martindale Test Equipment complies with EN ISO 12945-2/12947-1, ISO 20344, ASTM 4966/4970, etc. Martindale Fabric Abrasion Tester will meet your needs when you do Martindale rub test. Please contact us for more information about Martindale Machine or Martindale pilling test methods.

  • Tap Changer Analyzers & Winding Ohmmeters

    IBEKO Power AB

    Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Solid State

    AMETEK Drexelbrook

    The B/W Controls solid state relays are designed for controlling a wide variety of high and low resistance liquids, moist bulk materials, and general purpose use in applications requiring a low voltage control circuit.Supplied as compact package units, they combine performance-proven solid-state printed circuitry with an electromechanical load relay that features isolated double pole / double throw contacts for energizing pump motors, valves and other operating equipment.

Get Help